$ USD Advanced Ophthalmic Equipment Solutions Delivered from Miami EXPLORE EQUIPMENT English
MediWorks

MediWorks AL550 Optical Biometer for Myopia Management

SKU AL550

Fully automatic, non-contact optical biometer with 1,060 nm OLCR technology and Placido corneal topography. Designed for axial-length monitoring, pediatric myopia management, orthokeratology fitting, visual-quality analysis and keratoconus screening.

B2B pricing available for clinics, optical stores and distributors. Ships from Miami, FL.

Description

The MediWorks AL550 is an advanced optical biometer developed for comprehensive myopia management in children and adolescents. It combines 1,060 nm Optical Low-Coherence Reflectometry with 50-ring Placido corneal topography to obtain ocular biometry and anterior corneal measurements in a single examination.

Its long 1,060 nm wavelength supports reliable axial biometry, while the Placido system analyzes up to 125,600 points across the anterior corneal surface. The instrument can obtain up to 21 parameters during one measurement, including axial length, corneal curvature, anterior chamber depth, central corneal thickness, lens thickness, white-to-white distance and pupil diameter.

The AL550 provides axial-length and AL/CR ratio trend curves that can be compared with age- and sex-specific percentile references for European and Asian populations. These functions help professionals document changes over time, evaluate the response to myopia-control strategies and communicate progression information to patients and their families.

For orthokeratology, the system supplies flat and steep keratometry, astigmatism, corneal eccentricity and sagittal-height information. It can simulate lens fitting and generate tangential-curvature difference maps to compare the cornea before and after lens wear.

The AL550 also provides anterior corneal wavefront-aberration data up to the eighth Zernike order, visual-quality simulations and corneal maps with indices that support keratoconus screening.

Automatic XYZ tracking, autofocus, rapid capture, automatic right/left eye recognition and voice prompts simplify operation and help reduce operator dependence.

Key Features

  • Non-contact optical biometry
  • 1,060 nm OLCR technology
  • Designed for children and adolescents
  • Measurement of axial length and AL/CR ratio
  • Myopia-progression trend curves
  • European and Asian population references
  • Age- and sex-specific percentile comparisons
  • Documentation of myopia-control interventions
  • 50-ring Placido corneal topography
  • 125,600 corneal analysis points
  • 18,000 measured points
  • Up to 21 parameters in one measurement
  • Orthokeratology trial-lens selection support
  • Simulated orthokeratology fitting
  • Pre- and post-treatment difference maps
  • Wavefront-aberration analysis
  • Visual-quality simulation
  • Keratoconus screening
  • Automatic XYZ tracking and focus
  • Rapid image capture
  • Automatic OD/OS recognition
  • Voice-guided operation
  • Integrated 10.1-inch touchscreen
  • PDF and image export through USB or network

Clinical Functions

Myopia Progression Monitoring

  • Axial-length measurement
  • Axial length/corneal radius ratio
  • Chronological axial-length variation
  • Myopia and high-myopia probability curves
  • Comparison with population percentiles
  • Recording of myopia-control interventions
  • Evaluation of changes during follow-up

Orthokeratology Fitting

  • Flat and steep keratometry
  • Corneal astigmatism
  • Flat and steep eccentricity
  • Corneal sagittal-height difference
  • Trial-lens selection support
  • Simulated fluorescence fitting
  • Tangential difference maps before and after lens wear

Wavefront and Visual-Quality Analysis

  • Anterior corneal Zernike aberrations up to eighth order
  • Analysis diameter up to 12 mm
  • Retinal image simulation
  • Point Spread Function
  • Strehl ratio
  • Modulation Transfer Function

Keratoconus Screening

  • Anterior sagittal-curvature maps
  • Corneal elevation maps
  • Keratoconus indices
  • Corneal-morphology evaluation
  • Support for early screening of keratoconus and marginal degeneration

Technical Specifications

Specification Details
Measurement principle Optical Low-Coherence Reflectometry
Biometry wavelength 1,060 nm
Keratoscopic cone 50-ring Placido
Analyzed points 125,600
Measured points 18,000
Corneal coverage 9.8 mm
Dioptric power range 32.14–61.36 D
Dioptric accuracy ±0.1 D
Focus mode One-touch XYZ autofocus and tracking
OD/OS recognition Automatic
Monitor 10.1-inch touchscreen
Illumination Red and infrared
Database Internal
Axial-length range 0–40 mm
Axial-length tolerance ±10 µm
Axial-length resolution 1 µm
Corneal-thickness range 0.2–1.2 mm
Corneal-thickness tolerance ±10 µm
Anterior chamber depth 0.7–8 mm
ACD tolerance ±10 µm
Lens-thickness range 1.5–6.5 mm
Lens-thickness tolerance ±10 µm
White-to-white range 8–16 mm
White-to-white tolerance ±0.1 mm
Pupil-diameter range 1–13 mm
Corneal radius of curvature 5.5–10.5 mm
Curvature-radius accuracy ±0.02 mm
Axis range 0–180°
Power supply AC 100–240 V, 50/60 Hz
Power consumption 100 VA
Operating temperature +5 to +40 °C
Relative humidity ≤80%, non-condensing
Atmospheric pressure 800–1,060 hPa
Dimensions 307 W × 487 L × 577 H mm
Weight Approximately 21 kg
Operating system Linux
Internal storage 1 TB
Export options PDF or image to USB or network folder
Printer compatibility USB and network printers
Manufacturer Shanghai MediWorks Precision Instruments Co., Ltd.

Recommended Applications

  • Pediatric myopia management
  • Axial-length monitoring
  • Evaluation of myopia-control treatments
  • Orthokeratology lens fitting
  • Contact lens practices
  • Corneal topography
  • Keratoconus screening
  • Wavefront-aberration analysis
  • Visual-quality assessment
  • Patient and family education
  • Longitudinal clinical documentation

System Configuration

A typical configuration includes the AL550 optical biometer, integrated touchscreen, internal database, analysis software and operating accessories. Included components and software modules may vary by region and configuration; confirm the exact package before ordering.

Important Note

The AL550 is intended for use by qualified eye-care professionals. Its progression curves, probabilities, classifications and fitting simulations provide clinical decision support and must be interpreted with the patient’s complete ophthalmic examination.

Related products