$ USD Advanced Ophthalmic Equipment Solutions Delivered from Miami EXPLORE EQUIPMENT English
Reichert

Ocular Response Analyzer® G3 - Tonometer

SKU reichert-ocular-response-analizer-g3

Make a more confident glaucoma risk assessment, with Corneal Hysteresis. Only Ocular Response Analyzer® G3 from Reichert® measures Corneal Hysteresis (CH), a superior predictor of glaucoma progression, which is more associated with visual field progression than CCT or IOP. Ocular Response Analyzer helps add clarity to your glaucoma decision making process.

B2B pricing available for clinics, optical stores and distributors. Ships from Miami, FL.

Description

Unparalleled user experience

Measurements could not be quicker or simpler with Ocular Response Analyzer G3. A single touch of the intuitive user interface initiates a fully automated alignment and measurement, simultaneously displaying Corneal Compensated IOP (IOPcc), Corneal Hysteresis (CH), Goldmann correlated IOP (IOPg), and Waveform Score (WS).

 

Confidence, reliability and efficiency

The advanced, patent-pending Waveform Score feature, combined with Reichert’s unique intelligent averaging technique, enhances measurement reliability and repeatability so operators can be confident in the accuracy of the measurement results. Operators can easily access all functions through the integrated touch screen display, including export of patient data for effortless EMR integration. Delegate your tonometry and Corneal Hysteresis measurements to trained technicians with ease.

 

Non-contact saves time and money

Because the Ocular Response Analyzer G3 measurement is rapid and non-contact the use of topical anesthesia and/or fluorescein drops is not required, saving time and money. In addition, the risk of cross contamination is greatly reduced. The need for time-consuming sterilization of tonometer prisms, costly replacement of prisms, or use of expensive disposables is eliminated.

 

Unique design with patients in mind

Ocular Response Analyzer G3 is designed with no chinrest, which saves time by simplifying patient positioning. This unique design also makes patients more comfortable and less intimidated by not feeling confined in a chinrest.

 

Patented air pulse, maximum comfort

Reichert’s automatic, non-linear pressure ramp customizes the air pulse, in real time, for each eye being measured. This patented feature enables the softest possible air pulse, ensuring maximum patient comfort. In a pediatric study conducted on children between the ages of 4-18 years old found, “Overall cooperation was much better with ORA (89.8%) than with Goldmann applanation, and all the children we questioned preferred this (ORA) technique.

 

Designed and Assembled in the USA

Ocular Response Analyzer G3 is proudly designed and assembled in the USA at our state-of-the-art world headquarters in Buffalo, New York.

Technical Specifications

Catalog Number: 16170 

Dimensions: 26.7 W x 50.2 H x 35.6 cm D (10.5 x 19.75 x 14 in.) 

Weight: 10.4 kg (23 lbs) 

Voltage: 100/240 VAC Frequency 50/60 Hz 

Measurement Range: 7 - 60 mmHg (ISO 8612 tonometer standard) 

Communication Port: RS-232

Related products