$ USD Advanced Ophthalmic Equipment Solutions Delivered from Miami EXPLORE EQUIPMENT English
SBMSistemi

SBM Sistemi DEM100–DSLC200 Digital Slit Lamp Imaging and Dry Eye System

SKU SBM-DEM100-DSLC200

Digital slit-lamp imaging and dry-eye assessment system combining the DEM100 illumination module with the 3.1 MP DSLC200 camera.

B2B pricing available for clinics, optical stores and distributors. Ships from Miami, FL.

Description

The SBM Sistemi DEM100–DSLC200 is a modular imaging solution designed to upgrade a compatible slit lamp with digital photography, video recording, patient documentation and ocular-surface assessment capabilities.

The DSLC200 camera integrates into the slit lamp’s optical path through a premium optical image splitter. Unlike conventional eyepiece-mounted cameras, this arrangement preserves the natural binocular viewing experience while capturing consistent digital images and video. Its 3.1-megapixel camera uses a 1/1.8-inch sensor and connects directly to a workstation through USB 3.0 SuperSpeed without requiring a separate acquisition card.

The DEM100 supplements the imaging system with electronically controlled white diffused and near-infrared illumination. In combination with the applicable software, it allows the slit lamp to support tear-film interferometry, meibography, tear-meniscus evaluation, blink analysis, eyelid-margin documentation and ocular-redness classification.

The system can be installed on many slit-lamp models using the corresponding optical coupling. Separate coupling designs are available for Haag-Streit-style systems and other compatible slit lamps. Compatibility must be confirmed before ordering.

System Components

DEM100 Illumination Module

The DEM100 supplies the dedicated illumination required for ocular-surface and dry-eye imaging.

  • White diffused illumination
  • Near-infrared—NIR illumination
  • Electronic illumination control
  • Power supplied through USB cable
  • Designed for meibography and tear-film imaging

DSLC200 Digital Camera

The DSLC200 captures still images, multishot sequences and clinical video directly through the slit-lamp optical system.

  • Camera resolution up to 3.1 MP
  • 1/1.8-inch image sensor
  • Optical focus adjustment
  • Electronic ISO management
  • Single-image acquisition
  • Multishot acquisition
  • Video recording
  • USB 3.0 SuperSpeed connection
  • No separate acquisition card required

Key Features

  • Converts a compatible slit lamp into a digital imaging system
  • Adds dry-eye and ocular-surface assessment capabilities
  • Optical image splitter integrated into the beam path
  • Preserves binocular observation through the eyepieces
  • High-quality still-image and video recording
  • White diffused and near-infrared illumination
  • Fast USB 3.0 data transfer
  • No external image-capture card required
  • Adjustable optical focusing
  • Digital zoom through the software
  • Clinical archiving and patient follow-up
  • Patient-management software integration
  • Multilanguage software interface
  • Compatible couplings for multiple slit-lamp designs
  • Compact retrofit configuration

Available Examinations

Depending on the software package supplied, the system can support:

  • Tear-film interferometry
  • Automatic lipid-layer interferometry*
  • Tear-meniscus evaluation
  • Automatic NIBUT
  • Infrared meibography
  • 3D meibography*
  • Blink-quality analysis*
  • Blepharitis and eyelid-margin documentation
  • Bulbar-redness classification
  • Anterior-segment imaging
  • Meibomian gland-loss assessment
  • Clinical reporting and follow-up comparison
  • Customizable diagnostic and treatment protocols

*Available in the Plus configuration.

Software Configuration Comparison

Examination Basic Plus
Interferometry Manual Automatic
Tear-meniscus evaluation Yes Yes
Automatic NIBUT Yes Yes
Meibography Yes Yes
3D meibography — Yes
Blink-quality analysis — Yes
Blepharitis examination Yes Yes
Ocular-redness classification Yes Yes
Anterior-segment imaging Yes Yes

Technical Specifications

DEM100

  • Light sources: White diffuser and near-infrared—NIR
  • Lighting control: Electronic
  • Power source: USB cable
  • Primary application: Ocular-surface and dry-eye illumination

DSLC200

  • Image resolution: Up to 3.1 MP
  • Sensor: 1/1.8 inch
  • Acquisition modes: Single images, multishot and video
  • Focus: Manual optical adjustment
  • ISO control: Electronic
  • Connection: USB 3.0 SuperSpeed
  • Acquisition card: Not required
  • Installation: Optical image splitter with model-specific slit-lamp coupling

Optional Accessories

  • Haag-Streit-style coupling
  • Couplings for other compatible slit lamps
  • Protective device cover
  • Ophthalmic instrument table
  • 7 m powered USB 3.0 extension cable
  • Preconfigured mini computer

Published Mini Computer Configuration

  • Intel Core i7-12700 processor
  • 16 GB DDR4 RAM
  • 512 GB SSD
  • Intel UHD 770 graphics
  • Ethernet, Wi-Fi 6 and Bluetooth 5.2
  • Windows 11 Pro

Recommended Applications

  • Digital slit-lamp photography
  • Anterior-segment video recording
  • Clinical documentation
  • Patient-record integration
  • Dry-eye assessment
  • Tear-film evaluation
  • Meibomian gland examination
  • Eyelid-margin documentation
  • Contact-lens follow-up
  • Treatment comparison
  • Patient education

Important Note

The slit lamp and computer are not necessarily included. The correct optical splitter, mechanical coupling and software license must be selected according to the slit-lamp manufacturer and model.

The available examinations depend on the Basic or Plus software configuration. Images, measurements and software-generated suggestions must be interpreted by a qualified eye-care professional and should not be used as the sole basis for diagnosis or treatment.

Related products